Fire Detection and Alarm Systems
Fire Protection · Fire Detection and Alarm Systems

Fire Detection and Alarm Systems

Design, installation and maintenance of fire detection and alarm systems, delivered in line with BS 5839 and using EN54-compliant equipment where specified.

Standard
BS 5839-aligned
Equipment
EN54-compliant range
Technology
Wireless detection
Coverage
Design to maintenance
Home/Divisions/Fire protection · DefendX/Fire Detection and Alarm Systems
BS 5839-aligned. EN54-compliant equipment.

Fire detection and alarm systems built on current technology.

DefendX focuses on the latest fire detection technology rather than legacy wired panels. Systems are designed and delivered in accordance with the applicable fire strategy and relevant BS 5839 recommendations, using wireless, EN54-compliant detectors, call points and control panels that cut installation disruption without cutting compliance.

Every system is designed to the building's own fire strategy, commissioned and tested before handover, then kept compliant through a scheduled maintenance programme.

DefendX designs, installs and maintains fire detection and alarm systems using the latest wireless technology. Systems are designed and delivered in accordance with the applicable fire strategy and relevant BS 5839 recommendations, using EN54-compliant equipment where specified, and backed by scheduled maintenance and rapid fault response.

At a glance

Standard
BS 5839-aligned
Equipment
EN54-compliant range
Technology
Wireless detection
Coverage
Design to maintenance
What it covers

The work, line by line.

Every line is delivered against written assignment instructions and reported into the AOG weekly review.

System design

Detection and alarm strategy matched to the building's fire strategy and occupancy.

EN54-compliant installation

Detectors, call points, sounders and control panels installed from an EN54-compliant range.

Commissioning and testing

Full system test and handover documentation on completion.

Maintenance and fault response

Scheduled testing and rapid response when a fault is reported.

What is included

Inside the service.

  • System design against the building's fire strategy and current occupancy
  • Installation of EN54-compliant detectors, call points, sounders and control panels
  • Wireless fire detection, reducing disruption versus traditional wired installs
  • Commissioning, full system testing and handover documentation
  • Scheduled maintenance and testing to keep the system compliant
  • Fault diagnosis and rapid response repairs
Why AOG

What you get that you would not elsewhere.

Systems designed and delivered in accordance with the applicable fire strategy and relevant BS 5839 recommendations

Wireless systems cut installation disruption and time versus traditional wired alarms

Every design is matched to the building's fire strategy, not a generic panel and detector count

Commissioning and testing documentation held centrally, ready for audit

Runs alongside DefendX fire risk assessments and passive fire-stopping for one fire-safety record

One point of contact for design, installation, maintenance and fault response

Where it is deployed

Sectors using Fire Detection and Alarm Systems.

Proof

Operational, not aspirational.

100%
systems commissioned and tested before handover

Every installed system is tested and commissioned before handover, with system information retained against the client record.

Questions

Frequently asked questions

What types of fire detection and alarm system does DefendX install?

DefendX designs and installs systems using EN54-compliant detectors, call points, sounders and control panels, including wireless detection technology, matched to the building's fire strategy.

How is a system design matched to a building?

System design is based on the building's fire strategy and current occupancy, rather than a generic panel and detector count applied regardless of layout.

What maintenance does a fire alarm system need?

Systems require scheduled maintenance and testing to remain compliant, with fault diagnosis and rapid response repairs available where an issue is identified between scheduled visits.

Can DefendX install a temporary system during works?

Temporary fire detection arrangements during construction or refurbishment works need to be specified against the site's changing layout and current fire strategy. Speak to DefendX about the specific project before assuming a standard temporary system will meet the requirement.

What should we do if we get frequent false alarms?

Frequent false alarms usually point to a design, detector-type or environmental issue that should be investigated by a competent engineer rather than worked around, since it can lead to alarms being ignored.

Talk to DefendX about fire detection and alarm systems.

Tell us the building and the current system, if any. We will come back with a design and a quote.